Log Book for April 3, 2004
Engineering Report
James Russell & Peter Collins Reporting
Generator/Electricity:
China Special:
Voltage: 220
Hobbs meter reading: 579
We have been refueling "China Special" while it is still running.
Fuel Status:
Diesel:
Quantity: 17 gallons remaining
Consumed: 6 gallons
Propane Tank:
Reading: 75% (187.5 gal)
Consumed: 0 gallons
Gasoline:
Quantity: 42.5 gallons
Consumed: 0 gallons
Oil:
Quantity remaining: 13.5 quarts
Water:
Reading: Outside potable water tank level: 44 cm from the base
Consumed: 70 gallons in last 24 hours
Estimated Grey Water Used: 56 gallons in last 24 hours (assumed 80%)
Note: We used so much water today for a lot of dishwashing, lab equipment washing, several showers but most of the excess was due to using a lot of water to wash algae from bioballs in the Greenhab (see Greenhab report).
Time: 15:45
Inside Tank: 0 gallons
(Previous reading at 04/02/04: 50 gallons)
Time: 16:00
Inside Tank: 50 gallons (refilled)
Time: 19:40
Inside Tank: 30 gallons
HVAC: Nothing to report.
Transport: Nothing new to report.
Mars-Suits: Bill and Alex fixed the fan in backpack 6 - a battery connection had come loose. Also repair and cleaning of two helmets and the alteration of the collar on backpack 6 for a more comfortable helmet position.
Computers/Networking Infrastructure: Nothing new to report
|
|
|