Log Book for March 10, 2008
Engineering Report
Eric Harkleroad Reporting

Log Book for March 10, 2008

Engineering Report

Eric Harkleroad Reporting


Generator/Electricity:

Wendy

Hobbs Meter: 3556.5 hrs

Voltage: 117 VAC

[*] Frequency: 58 Hz

Oil Level: full

Oil Pressure: 30 PSI

[*] Water Drained: no


Notes/Comments:
Added an additional 1/2 qt oil to Wendy today. Photos of the backup
generator DP7500DE were sent separately.


Xantrex Inverter/Dynasty Batteries:

Time Voltage (Temp Comp) Load Temp Generator Running?
10:52 26.6 8A 8C yes
12:15 26.8 7A 8C yes
17:18 26.7 6A 9C yes
19:16 20 19A 11C yes



Fuel Status (as of 19:00):

Diesel:

Approximate Reading: 5/8




Propane Tank:

Approximate Reading: 70% (700 gallons = 2649.8 L)




Gasoline:

Quantity Remaining: 47 gallons = 177.9 L


Notes/Comments:
Don helped us with the gasoline pump today and it seems to be flowing
much more freely now.



Oil:

[*] GenSet Quantity: 17 quarts

[*] ATV Quantity: 13 quarts

[*] V'ger Quantity: 0 quarts



Water Status:

Outside Potable Water Tank Level: 395 gallons = 1495.2 L

Trailer Potable Water Tank Level: 7 inches from the base

Potable Water Meter Reading: 26786 gallons = 101395.7 L

Out to Toilet Meter Reading: 8252 gallons = 31237.1 L

In to GreenHab Meter Reading: 7823 gallons = 29613.2 L

Dishwasher Runs: 0



GreenHab:

Crops Watered: yes


Crop Condition:
We used about 4 gallons of potable water to water the plants in the
GreenHab (this amount was metered).


Observatory:

not used


Transportation:




Kawasaki ATVs

ATV 1
Used: no
Oil Checked: no
[*] Tire Status: NO VALUE SUPPLIED

ATV 2
Used: no
Oil Checked: no
[*] Tire Status: NO VALUE SUPPLIED

ATV 3
Used: no
Oil Checked: no
[*] Tire Status: NO VALUE SUPPLIED


Notes/Comments:
EVA did not use ATVs today.



Mars Surface Suits:
Pack #5 seems to have some sort of wiring issue--the fan does not stay
on when the switch is turned on. We will try to fix this.




GreenHab:
Greywater was pumped into the GreenHab this morning until full as
usual.

We noticed the propane heaters in the GreenHab appear to be under the
control of a thermostat as mentioned by Mission Support recently. The
heaters were off when temperature/humidity readings were taken at 11:38
and none of the crew shut them off manually, but they were on around
19:00.

Inside
Time Temp Hum
11:38 84F 13%
18:58 72F 16%
Outside
Time Temp Hum
11:38 61.3F 11%
18:58 46.9F 12%